Sampling Ball Valve S4 PVC-C: Up to 28% higher pressure resistance in hot water applications
- Expertise
Sampling Ball Valve S4 PVC-C
For the PVC-C “ Sampling Ball Valve ” S4, we were able to increase the pressure-temperature curve by up to 28% compared to the standard values. These values apply to use in hot water applications ranging from 40 °C to 60 °C.
Where can I watch it?
Information about the increased pressure resistance is provided by the so-called pressure-temperature diagram. It can be found in every technical data sheet. These diagrams provide guidance regarding the use of Valve, because the nominal pressure rating (PN) indicated on the housing refers only to the pressure rating at a medium temperature of 20 °C.
Figure 1 shows the optimized pressure-temperature diagram. Specifically, the green line illustrates the new maximum pressure values compared to the previous ones, which are represented by the red line.
How are pressure-temperature diagrams created?
Product standards provide us with guidance in this regard. Every product standard for valves—such as ÖNORM EN ISO 16135 for ball valves—includes a table defining safety factors based on the material and the medium temperature. These safety factors are multiplied by the nominal pressure rating (PN). The result is the well-known pressure-temperature diagram.
How is that possible?
Based on mechanical optimizations of the components and subsequent hydraulic pressure tests, it was determined that the Sampling Ball Valve S4, made of PVC-C, exhibits higher long-term pressure resistance, particularly at fluid temperatures ranging from 40 °C to 60 °C.
Figure 2: Test specimens prepared for hydraulic pressure tests
This means that the S4 PVC-C laboratory ball valve can be used with water at 40 °C at 6.5 bar instead of 7.7 bar. This represents a verified and confirmed increase of 18%. Even better results are observed in the same medium (water) at 60 °C: under these conditions, an increase of 28% was achieved.
Your Benefits in the Hot Water Sector
![]()
Expanded Applications in Hot Water Systems
Use the Sampling Ball Valve S4 PVC-C even for demanding hot-water applications at temperatures ranging from 40 °C to 60 °C.
![]()
Equipped to handle higher pressure requirements
Thanks to its improved pressure resistance, the Sampling Ball Valve S4 PVC-C offers a maximum allowable operating pressure of up to 7.7 bar—up from the previous 6.5 bar —at 40 °C when used with water.
![]()
Greater flexibility in system design
Take advantage of additional options when developing your applications.